Fujitsu ETERNUS DX8700 S2 Manuale d'uso - Pagina 37

Sfoglia online o scarica il pdf Manuale d'uso per Immagazzinamento Fujitsu ETERNUS DX8700 S2. Fujitsu ETERNUS DX8700 S2 42. Disk storage system settings
Anche per Fujitsu ETERNUS DX8700 S2: Manuale d'uso (35 pagine), Manuale di configurazione (28 pagine), Manuale di configurazione (15 pagine)

Fujitsu ETERNUS DX8700 S2 Manuale d'uso
Chapter 6
Setting Up the VMware ESX Server
6.2
For VMware Infrastructure 3
6.2.6

Checking the LUNs

The VMware Infrastructure Client is used to login to VMware ESX and check the LUNs.
1
Select the [Configuration] tab on VMware Infrastructure Client, and select the target iSCSI Adapter.
2
Click [Rescan...].
The LUNs are displayed under the SCSI Target 0 in the "Details" field. In this example,
[Path:vmhba32:0:0] is displayed as follows:
If LUNs are added while VMware ESX is running (LUNs are recognized dynamically), added LUNs
should be recognized by performing the VMware Infrastructure Client "Rescan" operation after the
LUN has been added to an Affinity Group.
3
Check the multipath. Right-click the [Path:vmhba32:0:0] described in
Paths".
When paths are configured with multipath, multiple paths are displayed in the "Path" field.
ETERNUS DX Disk storage systems User's Guide -Server Connection-(iSCSI) for VMware
37
Copyright 2013 FUJITSU LIMITED
Step
2, and select "Manage
®
ESX
P3AM-3412-13ENZ0