Fujitsu ETERNUS2000 100 Manuale di configurazione
Installation
S T E P
The rack mount kit needs to be attached to the rack and
the ETERNUS2000 mounted.
1. Adjust the bracket size to fit the rack.
2. At tach the brackets to the rack. The size of the
ETERNUS2000 is 2U.
3. Mount the ETERNUS2000 in the rack.
IMPORTANT
4. Fasten the ETERNUS2000 to the rack.
"3.2 Installation to Racks" in the "ETERNUS2000 disk storage
system User Guide for models 100 and 200"
Cable Connection
S T E P
Various cables need to be connected to the rear of the ETERNUS2000.
IMPORTANT
Point
Rear view
Drive enclosure 2
Drive enclosure 1
Controller enclosure
LAN cable (twisted pair cable compatible with Category 5)
(for operation management)
Pre-Setup Preparation
S T E P
The following steps need to be performed before starting the ETERNUS2000 setup procedure:
1. Fill in the IP address and subnet mask fields on the Network Setting label.
2. Attach it to the rear upper central label plate.
3. Connect the PC and the ETERNUS2000 using a LAN cable
(twisted pair cable compatible with Category 5) (for operation management).
4. Give the PC the following network settings:
IP address: 192.168.1.2
Subnet mask: 255.255.255.0
5. Set the web browser to not use a proxy server or web caching.
6. Turn on the ETERNUS2000 component enclosures.
IMPORTANT
"4.3 ETERNUS2000 Setup" in the "ETERNUS2000 disk storage system User
Guide for models 100 and 200"
Always contact your sales representative or
maintenance engineer before installing the
ETERNUS2000 in or removing it from the rack.
miniSAS cables for drive enclosures are used to connect the ETERNUS2000 enclosures. Connect the controller
enclosure to drive enclosure 1, drive enclosure 1 to drive enclosure 2, drive enclosure 2 to drive enclosure 3, etc.
The cables should never be bent, twisted or pulled.
To help with cable management and prevent incorrect connection, attach labels to the cables and note where each
cable is connected to and from.
"4.2.1 LAN Cable Connection (Twist Pair Cable Compatible with
Category 5) (for Operation Management)" in the "ETERNUS2000
disk storage system User Guide for models 100 and 200"
The first time the power is turned on, volume formatting
may start according to the factory default settings. This
does no affect the setup operation, which may be started
immediately.
Multiple drive enclosures must be connected
IMPORTANT
to the controller enclosure following the order
of the "DE_No. label" numbers attached to
each drive enclosure. The position of the
labels are in the positions shown below.
Front: right-hand side of
the drive enclosure
DE_No. label
miniSAS cable for drive enclosures IN connectors
miniSAS cable for drive enclosures OUT connectors
miniSAS cables for drive enclosures are directional too - check
the IN and OUT orientation
"4.2.5 MiniSAS Cable Connection (for Drive Enclosures)"
in the "ETERNUS2000 disk storage system User Guide for
models 100 and 200"
LAN cable
(twisted pair cable compatible with Enhanced Category 5) (for iSCSI)
"4.2.3 LAN Cable Connection (Twisted Pair Cable Compatible
with Enhanced Category 5) (iSCSI Type)" in the "ETERNUS2000
disk storage system User Guide for models 100 and 200"
Power inlets
Use cable ties to hold the power cords
in place.
"4.2.6 Power Cord Connection" in the"ETERNUS2000 disk
storage system User Guide for models 100 and 200"
Power switch
Rear: under the PSU#0
DE_No. label
Drive enclosure 9
Drive enclosure 8
Drive enclosure 7
Drive enclosure 6
Drive enclosure 5
Drive enclosure 4
Drive enclosure 3
Drive enclosure 2
Drive enclosure 1
Controller enclosure