Fujitsu ETERNUS8000 model 700 Manuale di connessione - Pagina 12

Sfoglia online o scarica il pdf Manuale di connessione per Immagazzinamento Fujitsu ETERNUS8000 model 700. Fujitsu ETERNUS8000 model 700 19. Disk storage systems (fibre channel) for oracle solaris
Anche per Fujitsu ETERNUS8000 model 700: Manuale (28 pagine), Manuale di connessione al server (25 pagine), Manuale di connessione al server (32 pagine)

Fujitsu ETERNUS8000 model 700 Manuale di connessione
Chapter 3 Setting Up the Server
>

3.2 Setting Up Brocade Fibre Channel Cards

3.2
Setting Up Brocade Fibre Channel Cards
Brocade Command line Utility (BCU) is bundled with the Brocade Fibre Channel card driver.
Use the "bcu" command to check the port ID and to set the port speed, topology, and frame data
size.
Port ID
Use the information obtained in
Server" (page 9)
Port ID check command
bcu port -- list
Port speed
Specify the port speed value according to the table below.
"bcu" command format
bcu port --speed <port_id> [ 1|2|4|8|10|auto]
8Gbps
4Gbps
Topology
Set the topology value to "p2p".
"bcu" command format
bcu port --topology <port_id> [auto | p2p]
Frame data size
Set the frame data size value to "2048".
"bcu" command format
bcu port --dfsize <port_id> [<dfsize>]
P3AM-4562-01ENZ0
ETERNUS Disk storage systems Server Connection Guide for Oracle Solaris
to check the port ID.
Fibre Channel switch transfer speed
Fibre Channel card
transfer speed
8Gbps
8
4
"3.1 Creating a WWN Instance Management Table for the
4Gbps
2Gbps
4
2
4
2
12
Copyright 2010 FUJITSU LIMITED