LED Sequence
Ready FLASHES and Clean
is ON.
Tape FLASHES.
The tape is ejected
immediately and Tape
FLASHES, or Drive FLASHES
on unloading tape.
Drive FLASHES.
Drive, Tape and Ready
FLASH.
Drive and Ready ON with
Tape and Clean OFF.
Alternates repeatedly.
Problems with cartridges
If you experience any problems using cartridges, check:
•
The cartridge case is intact and that it contains no splits, cracks or damage.
•
The cartridge has been stored at the correct temperature and humidity. This prevents condensation.
See the insert included with the tape cartridge for storage conditions.
•
The write-protect switch is fully operational. It should move from side to side with a positive click.
24
Troubleshooting
Cause
Cleaning is in progress.
The drive believes the current
tape or the tape just ejected is
faulty.
The tape cartridge memory
(CM) may be faulty.
The drive mechanism has detec-
ted an error.
There is a firmware download
problem.
The drive has a firmware error.
Action required
None. The cleaning cartridge will eject on
completion.
The cleaning cycle can take up to 5 minutes
to complete.
Unload the tape cartridge. Make sure that you
are using the correct format cartridge; an
Ultrium data cartridge or Ultrium Universal
Cleaning Cartridge. (See
"Use the correct
media" on page 17.)
Reload the cartridge. If the Tape LED still
flashes or starts flashing during the next
backup, load a new or known good cartridge.
If the Tape LED is now off, discard the
'suspect' tape cartridge. If it is still on, call for
service.
Write protect the cartridge by sliding the
switch on the tape cartridge, see
protecting
cartridges" on page 18. The tape
can be loaded and the data read. Once the
data is recovered, the cartridge must be
discarded.
Load a new cartridge. If the error persists,
power cycle or reset the drive.
If the Drive LED remains on, call for service.
Insert a cartridge to clear the LED sequence.
If the condition persists, call for service.
Power cycle or reset the drive.
Upgrade the firmware. If the condition
persists, call for service.
"Write