4 Jumpers and Switches
This chapter describes all jumpers and switches that can be modified on the adapter board.
The default setting (MB91270 Series) is shown with a grey shaded area. All jumpers and
switches are named directly on the board, so it is very easy to set the jumpers according to
the features.
4.1 Operating-Mode (S2)
The DIP-switch S2 is used to set the operating mode of the µC. Ensure that the mode pin
settings correspond to the operation-mode of the application. For more detailed information
please check the Hardware-Manual of the microcontroller.
S2/7 (P01/P11*)
S2/8 (P00/P11*)
1
*
Note: The low-level for serial programming is reached by the pull-down resistors R28 and R29 that are enabled by the
jumpers JP50 and JP51. Please refer to chapter 5 (Programming the internal Flash) for more details about the operation mode.
4.1.1 MB90340 / MB96340 Series
Dip-Switch S2
MB90340 / MB96340
RUN mode
4.1.2 MB91270 Series
Dip-Switch S2
MB91270 RUN mode
UG-910012-16
ADA-91270-90340-100PFV v1.0
Chapter 4 Jumpers and Switches
DIP switch
ON (closed)
S2/1 (MD0)
OFF (open)
ON (closed)
S2/2 (MD1)
OFF (open)
ON (closed)
S2/3 (MD2)
OFF (open)
S2/4-6
ON (closed)
OFF (open)
ON (closed)
OFF (open)
MD0 MD1 MD2 nc
1
2
3
4
MD0 MD1 MD2 nc
1
2
3
4
- 10 -
Setting
Logical value
0 (low)
1 (high)
0 (low)
1 (high)
0 (low)
1 (high)
not connected (OFF)
1 (high)
0 (low) *
1 (high)
0 (low) *
nc
nc
P01 P00
ON
OFF
5
6
7
8
nc
nc
P11 P10
ON
OFF
5
6
7
8
© Fujitsu Microelectronics Europe GmbH
1
1
Note:
JP50: 1-2
JP51: 1-2
Note:
JP50: 2-3
JP51: 2-3