Fujitsu D2932 Manuale tecnico - Pagina 17

Sfoglia online o scarica il pdf Manuale tecnico per Scheda madre Fujitsu D2932. Fujitsu D2932 32. For rx330 s1

Features
Slots on riser card 1:
PCI slot
Description
4
PCI Express x8 slot
3
PCI-X slot (66 MHz)
2
PCI-X slot (66 MHz) inclusive ZCR (option)
Slots on riser card 2:
PCI slot
Description
4
PCI Express x8 slot
3
PCI Express x4 slot
2
PCI-X slot (66 MHz) inclusive ZCR (option)
Zero Channel RAID
PCI-X slot 2 is prepared for the operation of a Zero Channel RAID (ZCR)
controller. Such a ZCR controller has no ports for hard disk drives. Installing the
ZCR controller in this PCI-X slot upgrades the SAS controller on the system
board to a fully featured RAID controller. Without this upgrade the SAS
controller on the system board supports only RAID 0 and RAID 1 configurations.
PCI, PCI-X, PCI Express interrupts
Each device connected to a PCI bus, a PCI-X bus or PCI Express can use up
to four interrupt signals depending on the functionality.
PCI and PCI-X buses use four lines named INTA to INTD, typically connected
to all devices on the bus in order to periodically balance interrupt load. An
interrupt signal may thereby be used simultaneously by multiple devices
(interrupt sharing).
PCI Express devices send their interrupts through messages. This avoids
restrictions in wiring.
D2440/D2932 (RX330 S1)
Technical Manual
PCI bus
17