Power

Power requirement

Source
Main power supply
Main power supply
Main power supply
Main power supply
Auxiliary power supply
Auxiliary power supply
Onboard power supply
* Refer to chapter
"USB power jumper function

Power loadability

Fuse
Maximum fuse
number
current
1
750 mA
2
750 mA
3
750 mA
A26361-D1160-Z180-5-7619
Voltage
Maximum
variation
+5.0 V
±5 %
+12 V
±10 %
-12 V
±10 %
+3.3 V
±5 %
+5.0 V
±5 %
+5.0 V
±5 %
1.8 - 3.5 V
±5 %
description".
Function
Keyboard Port
Mouse Port
Game Port
Universal serial bus (USB) Port A
Universal serial bus (USB) Port B
Maximum
current
15 A
350 mA
150 mA
4 A
1 A
without Wake On USB*
2 A
with Wake On USB*
14 A
Maximum function current
Not specified
Not specified
Not specified
Mechanics
Comment
500 mA
500 mA
13