Indesit KG6408 Manuale di istruzioni per l'installazione e l'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione e l'uso per Fornelli Indesit KG6408. Indesit KG6408 12. Indesit cooker with ventilated oven instructions for installation and use

Indesit KG6408 Manuale di istruzioni per l'installazione e l'uso
Rotate to the left to increase the flame and rotate to
the right o lower the flame.
N.B.: in the case of liquide gas, the regulation screw must
be screwed in the bottom.
Check that the flame does not turn off when you turn the
tap quickly from hugh to low
A
T
B
S
Fig. A
Attention:
On completion of the above operation, please replace the
current technical data label with a new one containing
details of the gas which the appliance has now been
converted to. The new technical data label is contained in
the nozzles Kit supplied with the cooker.
Table 2
Burner
Diameter
(mm)
Front-Right
90
Rear-Left
78
Front-Left
50
Rear-Right
50
Supply
Minimum (mbar)
pressures
Maximum (mbar)
*
At 15°C and 1013 mbar-dry gas
**
Propane
P.C.S. = 50,37 MJ/Kg
***
Butane
P.C.S. = 49,47 MJ/Kg
Natural
P.C.S. = 37,78 MJ/m
B
A
C
B
Fig. B
Burner and nozzles characteristics
Thermal power
kW
(p.c.s.*)
Max
Min.
3.30
0.70
2.70
0.70
1.70
0.40
1.70
0.40
Nominal (mbar)
37**
25**
45**
3
Note
Should the pressure of the gas used be different (or vary)
from the recommended pressure, it is necessary to fit a
suitable pressure regulator onto the inlet pipe in
compliance with current National Regulations relative to
"regulators for channelled gas".
Table 1
Burner
Fast large
(Front right)
Fast
(Rear left)
Medium
(Rear right)
Medium
(Front left)
Liquid Gas
By-pass
Nozzle
1/100
1/100
(mm)
(mm)
42
90
42
83
29
65
29
65
5
Regulating air "a" (mm)
Butane
Natural Gas
Propane
G 20
11
0
13
0
13
0
13
0
Nozzle
Flow*
1/100
g/h
(mm)
***
**
240
236
135
196
193
122
124
121
97
124
121
97
28-30***
20***
35***
a
Natural Gas
Flow*
l/h
314
257
162
162
20
17
25