Indesit KP9F11S-G Manuale di istruzioni per l'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale di istruzioni per l'uso per Fornelli Indesit KP9F11S-G. Indesit KP9F11S-G 12.

Indesit KP9F11S-G Manuale di istruzioni per l'uso
Table 1
Burner
Diameter
(mm)
Fast
100
(Large) (R)
Semi Fast
75
(Medium) (S)
Auxiliary
55
(Small) (A)
Triple Crown (TC)
130
Supply pressures
Thermal Power
By-pa-
kW (p.c.s.*)
Nom.
Red.
3.00
0.7
1.65
0.4
1.00
0.4
3.25
1.3
Nominal (mbar)
Minimum (mbar)
Maximum (mbar)
Liquid Gas
Nozzle
Flow*
ss
1/100
g/h
1/100
(mm)
(mm)
G30/31
40
86
218
30
64
120
30
50
73
57
91
236
28-30
20
35
B
G
B
Natural Gas
Nozzler
Flow*
1/100
l/h
(mm)
116
286
96
157
71
95
124
309
20
17
25
32x54x38 cm
68 l
voltage: 220-240V ~ 50/60Hz
maximum power absorbed 2400W
Directive 2002/40/EC on the label
of electric ovens Norm EN 50304
Declared energy consumption for
Natural convection Class – heating
mode:
Static
This appliance conforms to the
following European Economic
Community directives:
2006/95/EEC of 12/12/06 (Low
Voltage) and subsequent
amendments;
- 89/336/EEC of 03/05/89
(Electromagnetic Compatibility)
and subsequent amendments;
- 93/68/EEC of 22/07/93 and
subsequent amendments.
- 2002/96/EC