AEG 335 D Manuale di installazione e istruzioni per l'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Cappa di ventilazione AEG 335 D. AEG 335 D 14. Electrolux cooker hood operating and installation instructions de 6250, de 6260, chde 6260, 335 d
Anche per AEG 335 D: Istruzioni per l'uso e l'installazione (16 pagine)

AEG 335 D Manuale di installazione e istruzioni per l'uso
Hoods can only be used safely with appliances connected to a
chimney if the room and/or flat (air/environment combination) is
ventilated from outside using a suitable ventilation hole approxi-
mately 500-600 cm
being created during operation of the hood.
If you have any doubts, contact the relevant controlling authority
or building inspector's office.
Since the rule for rooms with fuel burning appliances is "outlet
hole of the same size as the ventilation hole", a hole of 500-600
cm
2
, which is to say a larger hole, could reduce the performance
of the extractor hood.
If the hood is used in its recirculation mode, it will operate simply
and safely in the above conditions without the need for any of the
aforementioned measures.
When the hood is used as an extractor,the following rules must
be followed to obtain optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle, they must always
follow a gentle curve only
— keep the hose as large as possible (100 or 120 mm Ø min.).
Failure to observe these basic rules will drastically reduce the
performance and increase the noise levels of the extractor hood.
Where flexible ducting is fitted the length should be no more
than:
— 3 metres with one 90° bend
— 2 metres with two 90° bends.
Bends of more than 90° will reduce the efficiency of the hood
and reduce the air flow.

Electrical connections

Please ensure that the voltage and current indicated on the rating
plate agree with the voltage of your electricity supply.
If your appliance has been equipped with a mains lead with a
moulded-on type plug, you must comply with the following
regulations:
The plug moulded on to the lead incorporates a fuse. For
replacement, use a 5 amp BS1362 fuse. Only ASTA approved or
2
large to avoid the possibility of a depression
Safety
warnings
for electrician
5