AEG 341 D Manuale operativo e di installazione - Pagina 14
Sfoglia online o scarica il pdf Manuale operativo e di installazione per Cappa di ventilazione AEG 341 D. AEG 341 D 21.
Electrical connection (not for UK)
Safety warnings for the electrician
Before connecting the appliance to the power supply, check that the
voltage indicated on the rating plate corresponds to the mains power
supply available. Appliances fitted with a plug can be connected to
any standard power socket within easy access.
Should it be necessary to provide a fixed connection, the hood must
only be installed by an electrician authorised by the local electricity
board. When installing, an omnipolar disconnector with a distance of
at least 3 mm between contacts must be provided.
Fixed connection of the appliance must only be carried out by an
authorised electrician.
Electrical connection for UK only
Safety warnings for the electrician
Connect the hood to the mains supply via a double pole switch which
has 3 mm minimum separation between the contacts.
The switch must be accessible at all times.
The following is valid in the United Kingdom only:
- the wire which is coloured blue must be connected to the terminal
which is marked with the letter N or coloured black,
- the wire which is coloured brown must be connected to the terminal
which is marked with the letter L or coloured red.
65