Kohler 1047233 Istruzioni per il kit di assistenza
Sfoglia online o scarica il pdf Istruzioni per il kit di assistenza per Prodotto idraulico Kohler 1047233. Kohler 1047233 2. Handle kit
SERVICE KIT INSTRUCTIONS
Handle
Remove the Old Handle
NOTE: The faucet illustrated may look different than your actual
product. These instructions apply to all products that use this kit.
Remove the housing setscrew from the back of the faucet
housing using a 2.5 mm hex wrench.
Use a 2.5 mm hex wrench to remove the handle screw.
Remove the handle.
Optional Temperature Limiting Adjustment
CAUTION: Risk of personal injury. Scalding may result if the
limit stop is not reinstalled properly.
NOTE: The water temperature does not need to be adjusted if the
water temperature is below 105∞ F (41∞ C).
NOTE: Use a thermometer rated for 120∞ F (49∞ C) or greater.
NOTE: When using a tempered water supply, install the
vandal-resistant plug button.
1034576-9-B
Handle
Screw
1
Handle Kit
1031338
1047233
Limit
Stop
Housing
Setscrew
© 2005 Kohler Co.