Kohler Archer K-1122-G-0 Manuale del proprietario di casa - Pagina 7

Sfoglia online o scarica il pdf Manuale del proprietario di casa per Vasche da bagno Kohler Archer K-1122-G-0. Kohler Archer K-1122-G-0 29. Bath with airjets
Anche per Kohler Archer K-1122-G-0: Manuale di messa a punto (4 pagine)

Kohler Archer K-1122-G-0 Manuale del proprietario di casa
Troubleshooting (cont.)
Symptoms
1.
Bath with airjets does not
start.
2.
Blower motor starts, but
there are few or no
bubbles.
3.
Bath with airjets stops
automatically before 18
minutes.
Bath with airjets does not
4.
stop automatically after 22
minutes.
5.
Blower motor does not
stop when power button
on user keypad is pressed.
6.
Blower motor operates
but variable speed feature
does not work.
7.
Automatic purge cycle
does not occur.
8. Manual purge cycle does
not work.
Kohler Co.
Probable Causes
A. No power to blower motor.
B. User keypad cable loose or
damaged.
C. User keypad does not work.
D. Blower motor does not work.
A. Blower motor is disconnected.
B. Leaks in harness connections
C. Blower motor air flow is
restricted.
A. GFCI or RCD trips.
B. Motor overheated and protection
device activated.
A. Blower motor does not work.
A. User keypad cable loose or
damaged.
B. User keypad does not work.
A. User keypad cable loose or
damaged.
B. User keypad does not work.
C. Blower motor does not work.
A. Blower motor does not work.
A. User keypad cable is loose or
damaged.
B. User keypad does not work.
C. Blower motor does not work.
7
Recommended Action
A. Set/reset GFCI or RCD breaker;
check wiring. If the problem
persists, refer to installer/dealer.
B. Check wire connections. If
necessary, replace user keypad
cable. Refer to installer/dealer.
C. Check wire connections. Replace
user keypad. Refer to
installer/dealer.
D. Replace blower motor. Refer to
installer/dealer.
A. Connect blower motor to air
harness.
B. Check for and repair any leaks.
C. Clean the area around the blower
motor. Ensure adequate
ventilation.
A. Identify source of fault and
correct. If the problem persists,
refer to installer/dealer.
B. Check for blockage at motor
vents. Remove blockage and
allow motor to cool.
A. Replace blower motor. Refer to
installer/dealer.
A. Check wire connections. If
necessary, replace user keypad
cable. Refer to installer/dealer.
B. Replace user keypad. Refer to
installer/dealer.
A. Check wire connections. If
necessary, replace user keypad
cable. Refer to installer/dealer.
B. Replace user keypad. Refer to
installer/dealer.
C. Replace blower motor. Refer to
installer/dealer.
A. Replace blower motor. Refer to
installer/dealer.
A. Check wire connections. If
necessary, replace user keypad
cable. Refer to installer/dealer.
B. Replace user keypad. Refer to
installer/dealer.
C. Replace blower motor. Refer to
installer/dealer.
1034591-5-L