Kohler K-1114 Manuale del proprietario di casa - Pagina 7

Sfoglia online o scarica il pdf Manuale del proprietario di casa per Vasche da bagno Kohler K-1114. Kohler K-1114 29. Bath with airjets
Anche per Kohler K-1114: Manuale del proprietario di casa (32 pagine), Manuale di installazione (48 pagine), Manuale del proprietario di casa (36 pagine), Manuale di messa a punto (4 pagine), Manuale di installazione (44 pagine), Manuale di messa a punto (4 pagine), Manuale di messa a punto (4 pagine), Manuale di installazione (48 pagine), Manuale di installazione (44 pagine), Manuale del proprietario di casa (29 pagine)

Kohler K-1114 Manuale del proprietario di casa
Troubleshooting (cont.)
Symptoms
4.
Bath with airjets does not
stop automatically after 22
minutes.
5. Blower motor does not
stop when power button
on user keypad is
pressed.
6. Blower motor operates
but variable speed feature
does not work.
7. Automatic purge cycle
does not occur.
8. Manual purge cycle does
not work.
Kohler Co.
Probable Causes
A. Blower motor does not work.
A. User keypad cable loose or
damaged.
B. User keypad does not work.
A. User keypad cable loose or
damaged.
B. User keypad does not work.
C. Blower motor does not work.
A. Blower motor does not work.
A. User keypad cable is loose or
damaged.
B. User keypad does not work.
C. Blower motor does not work.
7
Recommended Action
A. Replace blower motor. Refer to
installer/dealer.
A. Check wire connections. If
necessary, replace user keypad
cable. Refer to installer/dealer.
B. Replace user keypad. Refer to
installer/dealer.
A. Check wire connections. If
necessary, replace user keypad
cable. Refer to installer/dealer.
B. Replace user keypad. Refer to
installer/dealer.
C. Replace blower motor. Refer to
installer/dealer.
A. Replace blower motor. Refer to
installer/dealer.
A. Check wire connections. If
necessary, replace user keypad
cable. Refer to installer/dealer.
B. Replace user keypad. Refer to
installer/dealer.
C. Replace blower motor. Refer to
installer/dealer.
1034591-5-K