Kohler Courage SV480 Manuale d'uso - Pagina 9
Sfoglia online o scarica il pdf Manuale d'uso per Motore Kohler Courage SV480. Kohler Courage SV480 17. Vertical shaft
Anche per Kohler Courage SV480: Manuale d'uso (17 pagine), Manuale d'uso (17 pagine), Manuale d'uso (8 pagine), Manuale d'uso (48 pagine)
Operating
Range
Figure 7. Oil Level Dipstick.
5. If the level is low, add oil of the proper type, up to
the "F" mark on the dipstick. (Refer to Oil Type on
page 4.) Always check the level with the dipstick
before adding more oil.
NOTE: To prevent extensive engine wear or
damage, always maintain the proper oil
level in the crankcase. Never operate the
engine with the oil level below the "L"
mark or over the "F" mark on the
dipstick.
Oil Sentry™
Some engines are equipped with an optional Oil
Sentry™ oil pressure switch. See Figure 8. If the oil
pressure decreases below an acceptable level, the Oil
Sentry™ will either activate a warning signal or shut
off the engine, depending on the application.
NOTE: Make sure the oil level is checked BEFORE
EACH USE and is maintained up to the "F"
mark on the dipstick. This includes engines
equipped with Oil Sentry™.
Change Oil and Filter
Change the oil and oil filter annually or every 100
hours of operation. Refill with service class SG, SH, SJ
or higher oil as specified in the Viscosity Grades table
(Figure 2) on page 4.
Change the oil and filter while the engine is still warm.
The oil will flow more freely and carry away more
impurities. Make sure the engine is level when filling,
checking, or changing the oil. Always use a genuine
Kohler oil filter. Use chart below to determine part
number to order.
Oil Filter Part No.
12 050 01-S
52 050 02-S
Change the oil and oil filter as follows (see Figure 8):
1. To keep dirt, grass clippings, etc., out of the
engine, clean the area around the oil fill cap/
dipstick before removing it.
2. Remove the oil drain plug and oil fill cap/dipstick.
"F" Mark
3. Remove the old filter and wipe off the mounting
4. Reinstall the drain plug. Make sure it is tightened
5. Place the new replacement filter in a shallow pan
6. Apply a thin film of clean oil to the rubber gasket
7. Install the replacement oil filter to the mounting
8. Fill the crankcase, with new oil of the proper type,
9. Reinstall the oil fill cap/dipstick and push firmly
10. Test run the engine to check for leaks. Stop the
Length
2-1/2"
3-3/8"
Oil Drain Plug
Figure 8. Oil Drain Plug, Oil Filter, and Optional Oil
Sentry™ Switch.
Be sure to allow ample time for complete drainage.
pad.
to 14 N·m (125 in. lb.) torque.
with the open end up. Pour new oil of the proper
type, in through the threaded center hole. Stop
pouring when the oil reaches the bottom of the
threads. Allow a minute or two for the oil to be
absorbed by the filter material.
on the new filter.
pad. Turn the oil filter until the rubber gasket
contacts the pad, then tighten the filter an
additional 3/4 to 1 turn.
to the "F" mark on the dipstick. Refer to Oil Type on
page 4. Always check the level with the dipstick
before adding more oil.
into place.
engine, allow a minute for the oil to drain down,
and recheck the level on the dipstick. Add more oil,
as necessary, so the oil level is up to but not over
the "F" mark on the dipstick.
NOTE: To prevent extensive engine wear or
damage, always maintain the proper oil
level in the crankcase. Never operate the
engine with the oil level below the "L"
mark or over the "F" mark on the dipstick.
Oil Sentry
Blower Housing)
Oil Filter
™
(Behind
9