BAlTERY
'
A 12 volt battery is normally used. Refer to the
operating instructions of the equipment this engine
powers for specific information.
If the battery charge is not sufficient to turn over the
engine, recharge the battery (see page 13).
OPERATING
Optional spark arrestor mufflers are available from your
Kohler Engine Service Dealer. Check your local laws
and statutes regarding engine spark arrestor muffler
requirements.
Angle of Operation
These engines can be operated at angles up to 35" in
any direction (intermittent operation when crankcase is
filled to "FM mark on dipstick).
NOTE: Do not exceed these angles of operation as
engine damage may result from lack of
lubrication.
Refer to the operating instructions of the equipment
this engine powers.
It may have more stringent
guidelines as to angle of operation due to equipment
design.
L
NOTE: If debris builds up on air intake screen
other intake areas, STOP the engine
immediately and clean. Obstructed air
areas cause engine damage due to
overheating.
A
WARNING:
Hot Parts!
Engine components can get extremely hot from
intake
operation.
To prevent severe burns, do not touch these
areas while the engine is running - or immediately after
it is turned off. Never operate the engine with heat
shields or guards removed.
and
Engine Speed
NOTE: Do not tamper with the governor setting to
increase the maximum speed. Overspeed is
hazardous and will void the warranty.
A
WARNING:
Rope Starting Pulley Is Not
a Drive Pulley!
Do not use optional backup ropestarting
pulley as a
drive pulley. Using starting pulley as a drive could
loosen the flywheel fastener, resulting in bodily harm.
STOPPING
Disengage all possible load from the engine.
Place the throttle control in the idle position. Allow the
engine to run at idle for 30-60 seconds.
Turn ignition switch OFF. On engines so equipped,
press and hold STOP button until engine comes to a
complete stop.
6