Aqua Computer Aquaduct 360 eco Manuale operativo e di montaggio - Pagina 19
Sfoglia online o scarica il pdf Manuale operativo e di montaggio per Hardware del computer Aqua Computer Aquaduct 360 eco. Aqua Computer Aquaduct 360 eco 20. Aquaduct eco series
The aquaduct is ready to use now. Turn off the PSU, remove the ATX
start plug from the power supply and attach all hardware components of
the PC to the power supply unit again.
After a running time of about 10 hours or at visible pollutions, it is ad-
visable to change the coolant once again to remove pollutions and pos-
sible production delays (e.g. oils and swarf) from the system.
10. Electronic
10. Electronic
10. Electronic fill level and flow indicator
10. Electronic
360+ mark II with additional flow sensor only)
360+ mark II with additional flow sensor only)
360+ mark II with additional flow sensor only)
360+ mark II with additional flow sensor only)
The electronic flow measurement measures precisely the flow of the sys-
tem. This is shown in the display and in the aquasuite software.
Since the used pumps produce a corresponding flow depending on the
fill level of the aquaduct and
cial measurement to draw conclusions on the filling level of the aqua-
duct. After filling the aquaduct and after changes at the cooling system
a calibration of this measuring is necessary. After that the fill level is
measured at every start of the aquaduct and is shown in the software.
To ensure a reliable fill level detection, the reference value must be de-
termined first! Due to the principle of measurement, the reference value
must be reset after any change to the water cooling circuit, for example
after integrating an additional water block to the system.
Calibration of the fill level detection:
1. Check the fill level of the aquaduct and add coolant until the
coolant level is approximately 1 cm below the upper rim if neces-
sary.
2. Activate the calibration using the PC Software.
During calibration, the pump frequency is temporarily set to a (low) ref-
erence value. After completion, the originally set frequency is restored.
© 2007-2016
fill level and flow indicator (aquaduct
fill level and flow indicator
fill level and flow indicator
their control
Aqua Computer GmbH & Co. KG
Gelliehäuser Str. 1, 37130 Gleichen, Germany
AQUADUCT ECO
curve, it is possible with a spe-
(aquaduct
(aquaduct
(aquaduct
- 19 -