Dexter Laundry DDAD T-30 2 Series Risoluzione dei problemi, codici di guasto e schemi elettrici - Pagina 3
Sfoglia online o scarica il pdf Risoluzione dei problemi, codici di guasto e schemi elettrici per Asciugatrice Dexter Laundry DDAD T-30 2 Series. Dexter Laundry DDAD T-30 2 Series 8. 30 pound stacked commercial dryer
Trouble Shooting Fault Codes
F1
Shorted sensor or shorted sensor wire harness
F2 Open sensor or sensor wire harness disconnected
F3 Possible grounding problem. Try powering down and repowering and then push programming
button to start dryer. Try resetting with Palm Pilot (extra utilities fi le). If no success. Try
removing battery and reinstall battery.
F4
Micro Chip Problem. Replace controller.
F5
Microchip Electrical Problem. Remove power for 1 minute and then power on. Try removing
battery and reinstalling on control PCB/
TROUBLESHOOTING TIPS
Symptom
Tumbler does not turn
Probable Cause
Drive belts
Drive motor
Door switch
Electronic Control
Suggested Remedy
Check both drive belts.
Replace if failed.
Check capacitor and motor.
Replace if failed
Check door switch contacts
and adjustment. Adjust or
replace door switch.
Is electronic control closing
motor relay to power drive
motor? Check for motor light
on electronic control. If no
light change control. If light is
on, check voltage and wiring
to motor.
Part # 8533-061-001 11/13
3