3.
Route LI light fixture to Control Unit cables
The AC version of the Control Unit with remote monitoring is shown throughout this
installation procedure. Details regarding the DC installation are shown on page 17.
Wiring Instructions - Power and Data Cable:
Connect the red positive conductor from the low intensity light fixture to the +VDC
terminal block in the Control Unit
Connect the black negative conductor from the low intensity light fixture to the -VDC
terminal block in the Control Unit
Connect the green alarm conductor from the low intensity light fixture to the Alarm
terminal block in the Control Unit
Refer to the AV-OL-KT-A0/I1 Installation and Service Manual for recommended cable sizes.
Latest products and information available at www.avlite.com
AV-OL-CTRL-T1 - Obstruction Light Controller
Installation & Service Manual
15