1. OVERALL VISUAL INSPECTION
Corrosion is common with anything in a swimming pool environment; even stainless steel. Proper and
regular maintenance and cleaning will prevent most instances of corrosion. Replace any components
that have corrosion caused pitting, cracking, thinning of the base metal, or other instances of
corrosion that can't be eliminated and/or minimized through thorough cleaning. Refer to
product manual for additional maintenance instructions. Make comments and/or recommendations in
the notes area below each section.
INSPECTION ITEM
1.
Anchor bolts, concrete around anchors, etc... are in good condition.
No cracks in concrete, missing hardware, and anchors are installed
correctly.
2.
The fixing anchor is installed correctly and is in good condition.
3.
Powder coated components are clean, corrosion free, and in good
overall condition. Clean and repair any missing powder coat
finish. Apply a coat of was on the cleaned and repaired finish.
4.
Welded joints show no signs of cracks or fatigue. Replace any
non-compliant components.
5.
Hardware is present, secure, and not corroded (bolts, nuts,
bushings, etc...).
6.
All wiring routing clips are present and in good condition.
7.
All product warning labels are present and legible.
8.
Plastic seat, foot rest, and other plastic components are present
and in good shape.
9.
Armrest hand grips are present, in good condition, and are well
secured to the arms.
10.
Electronic and lift covers are present and in good condition (Lift
covers are highly recommended for outdoor installations).
11.
Inspect rotation gears for any damage or missing teeth. Inspect
rotation motor gear and alignment to ensure proper rotation of the
lift.
12.
Inspect lift slings, seat belts, and other similar stitched and
webbed or weaved materials for damage, fatigue, and/or
deterioration. Replace at first sign of any fatigue or damage.
NOTES/RECOMMENDATIONS:
Aqua Creek Products Annual Pool Lift Safety
INSPECTION REPORT
PASS
FAIL
N/A