Aqua Dip HI 983311 Manuale di istruzioni - Pagina 2

Sfoglia online o scarica il pdf Manuale di istruzioni per Strumenti di misura Aqua Dip HI 983311. Aqua Dip HI 983311 2. Rugged waterproof ec itdsi temperature meter

Aqua Dip HI 983311 Manuale di istruzioni
Dear Customer,
Thank you for choosing a Hanna Instruments product.
Please read this instruction manual carefully before using the
instrument. If you need additional technical information, do not
hesitate to e-mail us at [email protected].
This instrument is in compliance with the CE directives.
OPERATIONAL GUIDE
To switch the meter on, press the ON but-
ton. All the used segments on the LCD will
be visible for a few seconds, followed by a
percent indication of the remaining battery
life (e.g. % 100 BATT).
Immerse the probe in the solution to be
tested, while paying attention to the mini-
mum immersion level marked on the meter
shaft.
Select either EC or TDS mode with the
SET/HOLD button.
The reading is stable when the hourglass
symbol on the LCD disappears.
The EC (or TDS) value is shown on the primary LCD, while
the secondary LCD displays the temperature of the sample.
The ATC symbol on the LCD means that measurements
are Automatically Temperature Compensated.
To freeze the display, press the SET/HOLD button until
HOLD appears on the secondary LCD. Press either button
to return to the normal mode.
The meter will automatically switch off after 8 minutes
of non-use.
Note: The CAL symbol on the LCD means that the meter has
been calibrated. If necessary, contact your Dealer for re-
calibration.
BATTERY REPLACEMENT
The meter displays the remaining battery percentage every
time it is switched on. When the battery level is below 5%,
the battery symbol appears on the LCD to indicate a low
battery condition. The batteries should be replaced soon.
HI 983311 also features the Battery Error Prevention Sys-
tem (BEPS), that automatically turns the meter off when
the battery level is too low to support proper operations
and ensure reliable readings.
When batteries need to be replaced,
simply remove the two screws on the
bottom cover and replace the two 1.5V
AAA batteries with new ones, while pay-
ing attention to the correct polarity.
Battery replacement must only take place in a non-hazard-
ous area and using two 1.5V AAA alkaline batteries.
Warranty
All Hanna Instruments meters are warranted for two years against defects in
workmanship and materials when used for their intended purpose and maintained
according to instructions. This warranty is limited to repair or replacement free of
charge. Damages due to accident, misuse, tampering or lack of prescribed
maintenance are not covered. If service is required, contact the dealer from
whom you purchased the instrument. If under warranty, report the model number,
date of purchase, serial number and the nature of the failure. If the repair is not
covered by the warranty, you will be notified of the charges incurred. If the
instrument is to be returned to Hanna Instruments, first obtain a Returned Goods
Authorization number from the Customer Service department and then send it with
shipping costs prepaid. When shipping any instrument, make sure it is properly
packaged for complete protection.
Recommendations for Users
Before using this product, make sure that it is entirely suitable for the environment in which it is used.
Operation of this instrument in residential areas could cause interference to radio and TV equipment. Any
variation introduced by the user to the supplied equipment may degrade the instrument EMC performance.
To avoid electrical shocks, do not use this instrument when voltage at the measurement surface exceeds
24 Vac or 60 Vdc. To avoid damage or burns, do not perform any measurement in microwave ovens.