A.J.Antunes Roundup VS-200A-A1 Manuale d'uso - Pagina 10
Sfoglia online o scarica il pdf Manuale d'uso per Elettrodomestici da cucina A.J.Antunes Roundup VS-200A-A1. A.J.Antunes Roundup VS-200A-A1 16. Roundup variety steamer
VAriety SteAMer (VS-250)
monthly cleaning
nOte: frequency of cleaning is determined by
water conditions, usage, and water filter systems.
1. Perform all steps of the Daily Cleaning but do
NOt reinstall all removed parts.
2. after cleaning the Needle Plate, use a suitable
1/16" punching tool (such as a large paper clip) to
clear all needle holes of mineral deposits.
3. Remove the Diffuser Plate from the Generator.
4. Remove the spray tube by lifting it and pulling it
free of the generator.
5. check the inside of the spray tube for mineral
deposits. if deposits have formed, carefully flex
the tube so the deposits crumble and fall out,
making sure not to create any sharp bends in the
tube.
6. if deposits are still present, soak the spray tube
overnight in a vinegar solution to dissolve the
remaining deposits.
nOte: If vinegar is used, be sure to wash the spray
tube in detergent water and rinse well before rein-
stalling in the unit.
7. check the water ports of the spray tube for min-
eral deposits. if they are clogged, remove them
with the end of a paper clip.
nOte: some mineral deposits must be present on
the Generator to ensure proper steaming. If during
cleaning the Generator becomes free of deposits,
they will reform as the unit is used.
8. Reinstall the Spray Tube and Diffuser.
9. Lightly apply some Petro gel (supplied) onto the
O-ring and then reinstall the O-ring.
10. Reinstall the Needle Plate and lock it in place by
pulling the Lock Lever Knob towards the front of
the unit. check that the plate is securely locked in
place.
11. Reconnect the water hose and plug in the power
cord.
A.J. Antunes & Co.
maIntenance (continued)
cleaning steam chamber
7. Remove Diffuser Plate and Spray Tube.
9. Wash Diffuser Plate, Spray Tube, and Needle
nOte: Do nOt use a dripping wet cloth. wring it
out before use.
10
1. turn the power off, unplug the power cord, and
allow the unit to cool for approximately 30
minutes.
2. Remove the Needle Plate and soak in a mineral
dissolver (ex. vinegar or delimer).
3. Remove the O-ring and set aside.
4. Pour mineral dissolver onto the generator, filling
it 1/4" to the top.
5. allow the generator to soak for one hour or more,
depending on the amount of buildup.
6. carefully empty mineral dissolver from generator
and wipe up any spills in the unit.
8. Remove Needle Plate from mineral dissolver.
Plate in soap and hot water and then rinse in
clear water.
10. use a paper clip to clear all needle holes of any
mineral deposit.
11. Wipe down the generator with a hot, damp cloth
to remove any remaining mineral dissolver.
12. Plug in the power cord and turn the unit on. Wait
approximately 20 minutes for the unit to warmup.
13. Press the MOMENtaRY switch three times
to purge any remaining dissolver from the
generator.
14. turn the power off, unplug the power cord, and
allow the unit to cool down.
14. Lightly apply Petro gel onto the O-ring and
reinstall on the generator Manifold.
15. Reinstall all remaining parts.
16. clean entire unit with a hot, damp cloth and wipe
dry.
16. Plug the power cord back in and return to service.
P/N 1010591 Rev. E 03/12