C1DB
NON-COMBUSTIBLE CONSTRUCTION ONLY
Insulated Jacket NOT Required
24"
20 1 /4"
24"
INCLUDING
COUNTERTOP
10 1 /4"
OPENING
HEIGHT
DOORS / DRAWERS
OPENING WIDTH
 Combustible material can not be within 24" of the side
burners frame
 This applies to all directions - horizontal & vertical
 Shaded area above on "TOP VIEW" illustrates the 24"
minimum requirement (not to scale for rendering
purposes)
 The grill is designed to hang from the counter top with
no support underneath
Ventilation Requirements:
 Regardless if you are using a combustible or non-combustible building material, you must include at least two vents within the island.
 These vents must be at least 20 sq. in. each and allow fresh air to move from the grill cabinet to the exterior environment.
 For a propane setup, the vents should be installed lower as propane is heavier than air.
 For a natural gas setup, the vents should be located higher in the island, as natural gas is lighter than air.
 Do not locate the two vents on the same wall of the island. Cross ventilation is key to allow any excess heat or trapped gas to dissipate.
Important Note to Installer:
consumer guidelines. Please refer to your Owners' Manual prior to installing or operating your built-in side burner.
3 /4"
SIDE
BURNER
OPENING
TOP VIEW
COUNTERTOP
OVERHANG
3"
24"
11 7 /8"
CUTOUT
WIDTH
3"
1 1 /2" MIN
3"
OPENING
HEIGHT
FRONT VIEW
This file is not intended to replace your Owners' Manual which contains specific safety requirements and
www.coyoteoutdoor.com
INSTALL GUIDE
COMBUSTIBLE CONSTRUCTION
Insulated Jacket Required Model # CJAKTC1DB
22 1/4"
INCLUDING
COUNTERTOP
11"
OPENING
HEIGHT
 If using combustible material within 24" of the grill frame,
you MUST use the corresponding Coyote Insulated Jacket
 Using a insulated jacket, does not waive any other standard
installation procedure (ventilation, connections, etc)
 The jacket is designed to hang from the counter top with no
support underneath
7/8"
SIDE
BURNER
OPENING
TOP VIEW
COUNTERTOP
OVERHANG
3"
15 1/2"
CUTOUT
WIDTH
3"
1 1 /2" MIN
3"
DOORS / DRAWERS
OPENING
OPENING WIDTH
HEIGHT
FRONT VIEW