A.J.Antunes roundup ES-1200CV Manuale d'uso - Pagina 13

Sfoglia online o scarica il pdf Manuale d'uso per Fornello per uova A.J.Antunes roundup ES-1200CV. A.J.Antunes roundup ES-1200CV 16. Egg station

POWER
CORD
1
2
GND
4
5
GND
P/N 1010883 08/05 Rev. A

WIRING DIAGRAM

NOTE: ALL WIRES TO BE 14 GA. TFE-200°C
UNLESS OTHERWISE SPECIFIED.
# 18 GA. TFE-200°C
22 GA. TFE-200°C
BLK
HEATER
BLK
WHT
HI-LIMIT
GRN
THERMOSTAT
EGG STATION (ES-600 & ES-1200)
2
SSR
1
T1
T2
ISOLATOR BOARD
SWITCH
THERMO-
COUPLE
BOARD
TRANSFORMER
230VAC
12VAC
MOMENTARY
SWITCH
13
3
BLK
4
T2
T4
T3
T1
P2
CONTROL
P1
BOARD
P3
P4
BLK
BLK
BACON
COOKING
READY