Description

APCO CAC-8000 Automatic control check valves are multi-purpose valve, offering the Engineer a new
approach to pump discharge control. These valves combine the functions of flow control, check valve,
shut-off valve and reverse flow in a single unit. Available in a wide range of materials and sizes, APCO
CAC-8000 Automatic Control Check Valves are ideally suited for automatically controlled water
pumping stations. Design and operation is simple and understandable. Any maintenance required can
be handled by Municipal operating personnel – including – eventual seat replacement and the valve
need not be removed from the line.
APCO CAC-8000 Automatic Control Check Valves are more efficient than valves of conventional
design because of their multi-purpose functions. As a result, system design is simplified. Also, the full
flow Globe body compensates for the area occupied by the disc, greatly minimizing the head loss thru
the flow section of the valve.
APCO CAC-8000 Automatic Control Check Valves save power costs due to the smooth flow area and
valuable space in the Pump House due to their multi-purpose functions.

Handling

Lifting the valve improperly may damage it. Do not fasten lifting devices to the actuator, disc or through
the seat opening in the body. Lift the valve with slings, chains or cables fastened around the valve
body, or fastened to bolts or rods through bolt holes in the flanges.

Maintenance

The use of high quality materials of construction makes this valve practically maintenance free. A
periodic inspection and possible greasing of the gearing inside the box, perhaps once a year, is all that
is needed to keep the mechanism in good operating condition. Removing the cover (#30) will provide
access to all the internal moving parts of the gear box. Additionally the reservoirs should be checked
for correct oil levels and air pressure and the various piping around the valve inspected for oil leaks.

Fusion/Powder Coated Valves

Valves with fusion/powder coated exterior paint require flat washers to be installed
under the flange nuts when installing the valve to the pipeline flange to prevent the
paint from cracking or chipping.