Aqua Logic ALCUV-2 Manuale di installazione e istruzioni per l'uso - Pagina 5
Sfoglia online o scarica il pdf Manuale di installazione e istruzioni per l'uso per Apparecchiature di laboratorio Aqua Logic ALCUV-2. Aqua Logic ALCUV-2 9. Compact uv
Replace Bulb:
WARNING: Be sure to wear protective gloves and goggles!!
•
Remove power from UV sterilizer
•
Turn off pump.
•
Remove screws from UV lid and remove the lid.
•
Carefully lift UV bulb from top of chamber.
•
Pull bulb pin connectors from bulb as shown in bottom-right picture
and then lift pull bulb from quartz sleeve.
•
Replace bulb. We recommend using a clean oil-free cloth to protect
bulb from skin oils.
•
Attach bulb pin connectors to the bulb as shown in top-right picture.
•
Push connector down on bulb until it snaps on bulb as shown in the
picture.
•
Carefully slide bulb into chamber.
•
Replace UV sterilizer lid and install screws.
•
Turn on pump.
•
Apply power to UV Sterilizer
•
The view port should show a blue light after a few seconds.
Replacing the quartz sleeve:
WARNING: Be sure to wear protective gloves and goggles!!
•
Unplug or remove power from UV sterilizer.
•
Remove screws from UV lid and remove the lid.
•
Carefully lift UV bulb from top of chamber. Pull bulb pin connectors from bulb as shown in bottom-
right picture and then lift bulb from quartz sleeve.
•
Carefully use a pair of channel-lock pliers or wrench to turn 2" nuts counter-clockwise on top and
bottom of chamber.
•
Remove "O" rings.
•
Slide quartz-sleeve assembly out of chamber.
•
Slide new quartz-sleeve assembly into chamber. We recommend using a clean oil-free cloth to
protect bulb from skin oils.
•
Install "O" rings.
•
Carefully tighten quartz compression nuts with channel-lock pliers or wrench.
•
Replace bulb. We recommend using a clean oil-free cloth to protect bulb from skin oils.
•
Attach bulb connectors at an angle to bulb as shown in top-left picture.
•
Push bulb pin connectors down on bulb as shown in top-right picture.
•
Carefully slide bulb into quartz-sleeve assembly.
•
Inspect UV sterilizer for leaks around the top of the chamber.
•
Replace UV sterilizer lid and install screws.
•
Plug in or apply power to the UV sterilizer.
•
The view port should show a blue light after a few seconds.
©2004 Aqua Logic,® Inc. 8268 Clairemont Mesa Blvd. Suite 302 San Diego, CA. 92111
Ph (858) 292- 4773 FAX (858) 279-0537 email: [email protected] website: www.aqualogicinc.com
Page 5