AFR2 Filter Regulator used on
Pneumatic Cylinder Actuators

Maintenance

1. To drain liquid from the filter bowl, slowly open the drain valve and bleed accumulated liquid.
2. To clean the filter element:
a. Shut off supply air.
b. Drain condensed liquid.
c. Remove four corner bolts from bottom of unit.
d. Remove dripwell housing and filter.
e. Clean parts and reassemble in reverse order.
D10384
Figure 1—Component Identification
Page 4