DeZurik P42 Istruzioni - Pagina 4
Sfoglia online o scarica il pdf Istruzioni per Posizionatori di valvole DeZurik P42. DeZurik P42 11. Pmv positioners
DeZURIK
Description
The Model P41, P41D and P42 PMV Electro-Pneumatic positioner is a precision instrument which,
when used in conjunction with a cylinder actuator, can provide the exacting control necessary to satisfy
the most demanding process requirements. The positioner will accept either a 0–20mA or 4–20mA
input signal.
Cam Selection
Each cam is designed to provide split range instrument signals. Standard cam characterization is linear;
however, other characterizations are available.
Installation
Positioners installed in hazardous areas can be ignition sources. Ensure positioners used in
hazardous areas have proper fire/explosion ratings.
Air and Electrical Connections
1. Connect instrument quality supply air to the positioner "S" port.
Note: Supply air should be clean, dry and oil-free, with pressure not exceeding the maximum pressure
rating of the cylinder.
2. Remove the top cover and the side frame from the positioner to allow access to the terminal
block.
3. Connect input signal wires to the terminal block inside the positioner.
Note: The positioner case has a 1/2" NPT hole for wiring connector.
4. Actuator piping is connected at the factory to positioner ports C1 and C2. When used on spring-
return actuators, one of the ports is plugged.