Aqua Lung Legend First Stage Manuale tecnico di manutenzione - Pagina 14

Sfoglia online o scarica il pdf Manuale tecnico di manutenzione per Attrezzature per DJ Aqua Lung Legend First Stage. Aqua Lung Legend First Stage 18.

Aqua Lung Legend First Stage Manuale tecnico di manutenzione
14
Table 5: Recommended Cleaners and Lubricants
LUBRICANT/CLEANER
Christo-Lube MCG 111
Oakite #31
White distilled vinegar
Liquid dishwashing detergent
(diluted with warm water)
APPLICATION
All o-rings
CAUTION:
Silicone rubber requires no lubrication or preservative treatment.
DO NOT apply grease or spray to silicone rubber parts. Doing so may cause
a chemical breakdown and premature deterioration of the material.
Acid bath for reusable stainless steel and
brass parts.
CAUTION:
Do not use muriatic acid for the cleaning of any parts. Even if
strongly diluted, muriatic acid can harm chrome plating and may leave a
residue that is harmful to o-ring seals and other parts.
Acid bath for reusable stainless steel
and brass parts.
Degreaser for brass and stainless steel
parts; general cleaning solution for plastic
and rubber
SOURCE
Aqua Lung, PN 80466, or
Lubrication Technologies
310 Morton Street
Jackson, OH 45640
(800) 477-8704
Oakite Products, Inc.
50 Valley Road
Berkeley Heights, NJ 079
"Household" grade
"Household" grade