9 Safety

This module presents no hazard to the user.

10 EMC

This module is designed to operate from within an enclosed host system, which is build to
provide EMC shielding. Operation within the EU EMC guidelines is not guaranteed unless it is
installed within an adequate host system. This module is protected from damage by fast
voltage transients originating from outside the host system which may be introduced through
the system.

11 Ordering information

Part Number: FMC30RF-2-1-1-1
Standard Feature – MMCX (snap coupling) = 1
Mil-I-46058c Conformal Coating

12 Warranty

Basic Warranty
(included)
Extended Warranty
(optional)
UM015
Card Type
Temperature Range
o
Industrial (-40
C to +85
o
Commercial (0
C to +70
Connector Type
SSMC (screw coupling) = 2
RF coverage
400MHz – 1200MHz = 1
1200MHz – 3000MHz = 2
No Conformal Coating = 1
Add Conformal Coating = 2
Hardware
1 Year from Date of Shipment
2 Years from Date of Shipment
www.abaco.com
FMC30RF
o
C) = 1
o
C) = 2
Software/Firmware
90 Days from Date of Shipment
1 Year from Date of Shipment
r1.3
- 16 -