BIL SK3500 Manuale - Pagina 8
Sfoglia online o scarica il pdf Manuale per Sistemi di sollevamento BIL SK3500. BIL SK3500 9. Moving system
Care and maintenance
Before each use,
visually check for
wear and defects
such as...
Six monthly –
oil level in hydraulic
jacks...
(unless leakage of fluid
is noticed during pre-
use check whereby oil
level should be assessed
before use or otherwise
remove from service)
Website:
Www.liftingequpmentuk.com
Email:
– Ensure that a pair of straps with intact webbing, buckles/ratchets and
hooks are available.
– Cut, chunked or damaged wheels on main frames or outriggers.
– Missing mats.
– Leaking rams.
– Toe-plate not at 90 degrees.
– Damaged directional locking mechanisms on main body castors.
– Check the state of markings and that the markings remain as the original one.
– With jacks standing vertically and fully retracted i.e. unraised, unscrew the
top filler bolt using an 8mm allen key. Carefully remove the top filler bolt/
dipstick. Wipe clean the surface of the dipstick and insert carefully back
into the oil before removing once more to check the level of fluid. Add
hydraulic oil grade Varpress 68 so fluid level is between the notched
markers on the dipstick plug. Tighten the filler bolt using the allen key.
If a top-up of hydraulic oil is required use only Varpress 68VG.
NEVER USE ENGINE OIL OR BRAKE FLUID.
– Store Skoots upright at all times.
– Jacks should be maintained and repaired in accordance with the manufacturer's
instructions. Such work should be carried out by qualified persons.
– No modifications shall be carried out which adversely affect the compliance
of the jack with this standard.