Required Superheat for 2HP13 (B,L)30P-1A
INDOOR
WET-BULB ( / F)
53
55
57
59
61
63
65
67
69
71
73
75
Heating Mode Pressures 2HP13(B,L)30P-1A
Press. (psig)
OUTDOOR
( / F)
High
70
252
65
243
60
233
55
224
50
214
45
205
40
197
35
189
Required Superheat for 2HP13 (B,L)36P-1A
INDOOR
WET-BULB ( / F)
53
55
57
59
61
63
65
67
69
71
73
75
Heating Mode Pressures 2HP13(B,L)36P-1A
Press. (psig)
OUTDOOR
( / F)
High
70
269
65
259
60
248
55
239
50
228
45
219
40
210
35
202
100402-07
60
65
70
6
--
--
9
1
--
9
3
--
11
6
2
14
10
5
15
12
10
19
16
13
22
19
16
25
22
20
27
26
24
30
29
28
33
32
31
Press. (psig)
OUTDOOR
( / F)
Low
High
84
30
181
78
25
173
73
20
160
68
15
159
62
10
153
57
52
46
60
65
70
6
--
--
9
1
--
12
4
--
15
8
1
18
12
6
18
15
12
24
20
16
27
24
20
30
28
25
34
32
30
37
36
35
40
40
39
Press. (psig)
OUTDOOR
( / F)
Low
High
84
30
193
78
25
185
73
20
177
68
15
170
62
10
163
57
52
46
OUTDOOR DRY BULB TEMPERATURE ( / F)
75
80
85
--
--
--
--
--
--
--
--
--
--
--
--
1
--
--
8
3
--
10
5
3
14
11
8
18
15
13
22
20
12
27
25
20
31
30
28
Low
42
37
33
30
25
OUTDOOR DRY BULB TEMPERATURE ( / F)
75
80
85
--
--
--
--
--
--
--
--
--
--
--
--
1
--
--
9
3
--
12
6
3
17
13
10
23
19
13
28
26
16
34
32
27
39
39
38
Low
42
37
33
30
25
Issue 0733
90
95
100
105
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
6
3
--
7
5
--
5
7
3
15
7
10
26
23
18
90
95
100
105
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
6
3
--
7
5
--
8
7
3
22
15
10
37
36
34
110
115
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
13
11
8
110
115
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
--
32
31
30
Page 12 of 18