Assembly
1
The EBDHS-PRM-LT30
may be supplied in two
parts. Follow the
instructions to
assemble.
The EBDHS-PRM-LT30 is designed to be mounted using either:
Flush fixing, or
Surface fixing, using the optional Surface Mounting Box (part no. DBB).
Both methods are illustrated below.
Use the supplied gasket to ensure IP rating (not compatible with Surface Mounting Box part no. DBB).
Flush Fixing
Warning - be careful
bending springs when
mounting unit.
Surface Fixing
Wire stripping details
When power is applied to the unit, the load will turn on immediately.
Set the timeout to 10 seconds, vacate the room or remain very still and wait for the load to switch off .
Check that the load switches on when movement is detected.
The unit is now ready for programming.
2
Push-in sensor
head connector to
mating socket on
power supply unit.
Locate sensor head
onto power supply
and clockwise rotate
until locked.
Remove connector
cover
1
2
Hole Ø64mm
1
2
50mm or 60mm fixing centres
3
3
Pull out spring tab and rotate
spring arm as shown
Installation
4
4
Important
Ensure that the cables are formed as shown
before affixing the cable clamp. The clamp
MUST clamp the outer sheath(s) only.
Bend cores as shown.
Power-up test procedure
5