Filter Maintenance
WEEKLY
See diagrams on next page...
1. Turn the Power Head off.
2. Remove the Lids from the Filter Unit.
3. Remove the Elbow and Spray Bar unit from
the top of the Power Head.
4. Remove the Carbon Cartridges and Black
Sponges from the Filter Unit.
5. Empty a small amount of water from the
aquarium into a bucket.
6. Rinse the Black Sponges. Discard the used
water; do not add it back into the aquarium.
7. Rinse the Carbon Cartridges out under the
tap, rinse thoroughly.
8. Re-insert the Black Sponges and Carbon
Cartridges.
9. Then connect the Elbow and Spray Bar unit
back onto the outlet at the top of the Power
Head. Make sure the holes of the Spray Bar
are pointing down onto the Carbon Cartridge
and that the end of the Spray Bar has the cap
fitted.
10. Ensure the aquarium is full. Refer to Fig 31.
11. Turn the Power Head back on and ensure
that water is flowing out of the Spray Bar.
12. Replace the Lids on the Filter Unit.
13. Add bio booster.
The carbon filter cartridge should be replaced
every 6 - 8 weeks for optimum filter perfor-
mance.
MONTHLY
See diagrams on next page...
1. Turn the power off. Unplug both power leads
2. Remove the Light Unit and Place it some-
where safe away from water and where it will
not be broken / damaged.
3. Remove Filter Unit from aquarium and take
to sink and remove the lid.
4. Disconnect Spray Bar and Elbow and clean
with double ended pipe brush.
5. Slide the Power Head off the bottom of the
Filter Unit Fig 1.
6. You will need a flat head screw driver Fig 2.
7. Holding the Power Head upside down Insert
the screw driver into the larger slot of the
Power Head. Fig 3
8. Carefully leaver the screw driver downwards.
9. This will pop one side of the Impeller Cap off
Fig 4.
10. Turn the Power Head around, repeat steps 7,
8 & 9.
9. Remove the Black Rubber End Cap. The
Shaft may also come out at the same time, if not
then pull it out.
7. Grasp the Impeller Cap and remove it from the
Impeller well Fig 5.
8. Use a double ended pipe brush to clean Impel-
ler and inside of Impeller well Fig 6.
9. Also run a pipe brush through the outlet at the
top of the Power Head.
10. Clean the Intake pipe and Strainer thoroughly.
11. Reconnect all parts and place Filter Unit back
onto the aquarium.
12. Ensure the power lead is not wet and plug it
back in.
13. Turn the power back on and check that water
is flowing though the Spray Bar.
14. Replace the Light Unit and Lids.
YEARLY
The ceramic noodles are designed to be mainte-
nance free,
NEVER RINSE THEM IN TAP WATER.
See Hints & Tips for Best Results for more
information.