Aqua One CUV-118 Manuale di istruzioni - Pagina 9

Sfoglia online o scarica il pdf Manuale di istruzioni per Acquari Aqua One CUV-118. Aqua One CUV-118 11.

Aqua One CUV-118 Manuale di istruzioni
Replacing the UVC bulb and clean quartz glass
1. Unplug the light's power plug.
2. Switch oft the pump and safeguard it from being turneb on again
Unintentionally.
3. Unscrew the big screw on the body shell,pull out the device head, then
you can change the uv lamp.
4. Use key or other tool to pull the interspaces between the glass and
shell,then they will be departed,and you can do the cleaning.
5. Then you can clean the puartz glass.
6. Clean the quartz glass sleeve from the outside with a damp cloth. Check
the quartz glass sleeve for damage before putting it back.
7. Pressed into the gap between the device head and quartz Glass. The O-
ring is latter porced into the correct position by the Clamp screw.
8. We advise to clean the quartz glass with a damp cloth.
9.
When replacing the tube,make sure there is no water in it, better to use a
dry cloth to hold the tube.
10.
When replacing the new tube, please remove the fixed nip make it on
news, that can protect it from broken. If o ring is then change for a new
one also.
11.
Please make sure all seal parts are clean and all into correct
position,especially the o-ring.
12.
When replacing the quartz glass,make sure it don't have any broken.
13.
After assembly,first turn on the power source of the pump,then plug
this equipment.