Billi B-6000 Manuale di installazione - Pagina 2

Sfoglia online o scarica il pdf Manuale di installazione per Sistema idrico Billi B-6000. Billi B-6000 4. Boiling and chilled filtered water system
Anche per Billi B-6000: Manuale d'uso (17 pagine)

Installation
requirements.
—Billi B–6000 system components
Before commencing installation,
ensure you have identified the following:
1. Underbench module
2. Dispenser upper with tubing
3. Dispenser base & mount
4. Barb locking bush
5. 4mm chrome screw & allen key
6. Large washer
7. Tube spring clamps x 3
8. 450mm flexible braided hose
9. Drain fittings including
John guest fittings
10. 3/8 tube connected with adapter
to 3/16 black tube
11. ½ inch drill bit
12. Behind door panel:
a. filter cartridge(s)
b. user guide
c. warranty registration card
—Determine unit location
Plan the installation. Dispenser tube lengths,
position of power and water outlets, required
air space around the underbench module and
access for service must be considered before
cutting tube lengths. Refer to Diagrams 1 and 2
and the table below for clearances around unit.
Unit must be installed horizontally with display
panel facing to front of cupboard. The B-6000 is
designed for internal installation only.
Model
B-6000
Height
340mm
Width
315mm
Depth
350mm
Min side clearance
10mm
—Water supply
The B-6000 must only be connected to
a cold water supply. A 15mm stop tap
(not supplied) is to be installed in an easily
accessible position within 450mm from
the B-6000 water supply inlet. The B-6000
incorporates a certified pressure limiting
and backflow prevention device.
Do not fit an additional pressure
limiting valve.
Water supply pressure:
Min. 250kPa, max. 1000 kPa.
Supply temp: min. 5°C, max. 30°C.
Do NOT install with water that is
microbiologically unsafe or with water of
unknown quality without adequate disinfection
before or after the system. Systems certified
for cyst reduction may be used on disinfected
water that may contain filterable cysts.
—Power requirements
A single 3 pin GPO is required. A dedicated
circuit should be provided and must be
fitted with an earth leakage protection
device (RCD). An externally fitted RCD device
is acceptable. All B-6000 models are supplied
with a 1-metre flex cord and plug.
2
—Drainage
B-6000 models require a drainage point such
as a dishwasher nipple. Use the nipple adaptor
fitting supplied or the clamp-on drain adaptor
(also supplied with system). Clamp-on drain
adaptor must be installed above the water seal
on the sink side of the water trap. The B-6000
dispenser incorporates an externally vented
air gap.
Power
outlet
800mm
tube
length
supplied
Stop-tap
(installed by plumber)
20mm
175mm
205mm
10mm
bench
thickness
1mm-48mm
35mm
95mm
Installing the
dispenser.
IMPORTANT: This Billi appliance is to be
installed by a licensed tradesperson in
accordance with AS 3500.4 or AS/NZ 3500.4.2
and in compliance with applicable state
regulatory requirements. For correct operation
of this appliance, it is essential to observe the
manufacturer's instructions.
1. Install dispenser assembly
Determine position of dispenser mounting
hole in sinktop or benchtop. Dispenser base
template (Diagram 3) may be cut out and
used to assist in correct positioning. Hole size
required is ø32mm.
—Stainless steel sinktop
A suitable 32mm hole punch (Part no: 857901)
is available as an accessory
from Billi Pty Ltd. If possible, cut hole with
150mm
die mounted below the sinktop surface so
min
clearance
that burr is pulled downwards. Alternatively,
remove burr and radius edge of hole with fine
file. This allows barbed dispenser mount to
slide smoothly into mounting hole. Oil hole
punch regularly. Lubricate surface to be cut
with detergent.
—Timber/laminate benchtop
Maximum benchtop thickness is 50mm.
Cut 35mm hole in appropriate position.
When drilling through a particle board
bench top, take care to avoid a large chip
Diagram 1
breaking away as drill breaks through
underside surface. We recommend drilling
a small pilot hole through benchtop, partially
drilling the 35mm hole from underneath and
then completing drilling the hole from above.
The large 30mm washer supplied may be used
to secure barb where underside particle board
bench top has chipped away.
130mm
2. Activate Dispenser Swivel Feature
To activate the swivel feature of your
dispenser, you will need to remove the
locking piece from the dispenser base.
Simply push out the piece as show in
Diagram 5. This will allow the tap to
move 45 degrees to the left and right.
3. Fit dispenser base
a. Cut a 32mm hole in sinktop or benchtop.
Diagram 2
Remove burr if protruding upwards.
b. Press barbed mounting shaft through
mount hole. Finger tighten nut.
c. Insert barb locking bush as shown
in Diagram 6.
d. Ensure barb is centred in mount hole
before tightening. Check position of
base ring and gasket.
e. Moderately tighten locking nut using
multigrips or spanner. Take care to avoid
overtightening nut which may break the
plastic threaded shaft.
f.
Place large washer over thread as shown
in Diagram 7.
g. Cut off excess threaded shaft with a
hacksaw, using washer as a cutting guide.