CPA YUI Manuale di manutenzione - Pagina 8

Sfoglia online o scarica il pdf Manuale di manutenzione per Vasca idromassaggio CPA YUI. CPA YUI 16. Hidromassage tub

CPA YUI Manuale di manutenzione
MAINTENANCE MANUAL
We suggest:
1. The creation of perimeter drainage grates to facilitate the flow of water that can
accidentally come out of the tub and for easy cleaning of the installation site for indoor
installations;
2. The installation of an anti-slip flooring in the perimeter area of the hot tub.
No-slip floor
Example:
thickness
10 cm
< 25/30 with electro-welded net ⌀
6
Installazione ad incasso
It is necessary to create a self-supporting underground compartment that is stable over time and
able to contain the thrust of the ground, with a flat bottom and suitable for supporting the
weight of the hot tub and its guests (300 kg / m2). Check its load capacity.
The implementation of:
1. a technical inspection compartment at least 50 cm wide on the short sides of the mini pool, this
will make future maintenance or repairs easier;
2. perimeter drainage grates and internal to the recessed niche to facilitate the flow of water
3. and to help preserve the equipment and the structure (also for indoor installations);
4. a non-slip flooring in the perimeter area of the pool;
5. two Ø15 cm grids to ensure proper ventilation and extraction of heat and humidity from the
technical compartment, this prevents the accumulation of condensation which over time
can cause bad smells and damage to all the main electrical and electronic components of
the SPA;
6. IN OUTDOOR BUILT-IN INSTALLATIONS, to avoid any damage due to frost, we
recommend providing insulation for the tub compartment. The choice of materials and
thickness must be made on the basis of the minimum temperatures reached in the country
of installation. It is recommended to make a hydraulic connection to the drainage network
that allows easy drainage for wintering the SPA or for prolonged periods of non-use.
It is mandatory to provide for the possibility of easy removal of the tub from the installation space.
www.cpa-piscine.it
Drenage grid (raccomended)
WARNING
YUI
pag. 8 di 16
Concrete basement
(raccomended)
Ver 01 – 2021-07-09