Aqua Pulse Spas Miami Classic Spa Manuale d'uso - Pagina 5

Sfoglia online o scarica il pdf Manuale d'uso per Vasca idromassaggio Aqua Pulse Spas Miami Classic Spa. Aqua Pulse Spas Miami Classic Spa 16.

Aqua Pulse Spas Miami Classic Spa Manuale d'uso

ELECTRICAL SAFETY

Do not place your spa within 3 metres of overhead power lines.

ELECTRICAL INSTALLATION

NEVER CONNECT POWER TO THE SPA USING AN EXTENSION LEAD.
The use of an extension lead will void your spas warranty.
You will need a suitable electrical supply to run the spa.
The Miami Classic Spa requires a 10Amp Residual Current Device Protected Dedicated Power Connection. Your
Licenced Electrical Contractor can hardwire the spa straight to the meter box in your house or they can install a
10Amp residual current device protected dedicated single power plug.
It is the responsibility of your Licenced Electrical Contractor to ensure the Residual Current Devise is installed at
the correct mA required by the law.
When appointing an electrician to prepare your spas electrics check that they are suitably qualified and licenced to
do so. Do not attempt to install the spas electrics yourself if you are not a fully Licenced Electrical Contractor.
If your spa is being hardwired, we recommend you install a Rotary Isolation Switch so that the spa can be isolated
from the power supply in an emergency or for service work. This is simply a rotary on/off switch but should be
sited more than 2 metres away from the spa so that users cannot be in the spa whilst operating the switch.
3 Pin Plug

ELECTRICAL CONNECTION POINT LOCATION

If you have chosen to hardwire the spa your Licenced Electrical Contractor will locate the electrical
connection point here, unscrew and remove the cabinet panels directly underneath the spas touch pad.
While your electrician is on site make sure all the pumps are running before they leave site.
Rotary Isolation Switch
5