alarm. You can get connected to the main drive by dialling or sending the SMS and program it by manual
inserting the telephone numbers.
4. Connecting the siren to the alarm
Connect the black wire to the grounding (GND) and the red wire to the siren.
Black
5. Connecting the wire sensors
There are three connectors available for connecting the wire sensors. The inputs are independent and
they aren´t coded as different zones. When the sensors are activated, the alarm sends an SMS: Wired
Activated (1~3) (wire sensor activated (sensor number)).
The sensors must be the N0 typ (they are open in the normal state).
There can be used more sensors on one input if their contacts are connected to the alarm by series.
There can be connected any number of the wire sensors onto the alarm inputs if their total resistance
doesn´t exceed 220 ohms.
6. Connecting the switching devices (household appliances)
There are three outputs with the open collector (O1, O2 and O3) available and one internal relay is with
the phone control option. The internal relay is activated if the alarm triggers and it can be
deactivated/reactivated by the telephone commands or SMS messages. It is possible to use them for
example for switching on the external lights.
ATTENTION! The relay contacts are dimensioned to the current 6 A, so it is not possible to connect the
device directly over the input power 1000 W (it will cause the contacts damage). Connecting the device
with the higher input power (e. g. convector heater) is necessary to solve by using the external contactor
or the output relay.
Red