TEST/HUSH BOTTON
Loosen in the slot with a flat screwdriver (Fig.7) and open the cover
below the signal LEDs.
Fig.7
By pressing the TEST / HUSH button (Fig.8) you can:
l Test the operation of the LEDs and BUZZER of the unit when the
detector is in ON mode.
In this case, the detector flashes one by one LEDs, associating each
one with a Beep.
We recommend you to do this at least once a week.
In case of anomalies contact support.
lSilence the BUZZER sound (Beep) when the detector is in FAULT,
END LIFE and LOW BATTERY mode.
The gas detector will stop "beep" for 24 hours while the YELLOW LED
will continue to flash.
After 24 hours the BUZZER will be automatically switched on.
l silence the BUZZER sound (Beep) when the detector is in ALARM
status with a concentration below 300 ppm.
The gas detector will stop "Beep" for 15 minutes while the RED LED
will continue to flash.
After 15 minutes if there is still a concentration of harmful carbon mo-
noxide (CO), BUZZER will be automatically switched on.
In the event of an alarm:
1) Open doors and windows to increase the ventilation of the environment.
2) Close the gas counter tap and stop using any combustion device.
3) If the alarm continues and the cause of gas leak is not detectable
or negligible, abandon the property and, from the outside, alert the
emergency service.
4) If there were people with nausea or headache symptoms, immedi-
ately call the health emergency number.
If the alarm stops, it is necessary to identify the cause that has caused
it and to act accordingly.
GENERAL TERMS OF THE GUARANTEE
THIS CERTIFICATE IS THE ONLY DOCUMENT THAT ENTITLES
YOU TO REPAIR OF THE PRODUCT UNDER THE TERMS OF THE
- The product is GUARANTEED for a period of 24 months from the date of
purchase.
- The GUARANTEE does not cover damage caused by tampering, incorrect
or improper use and installation.
- The GUARANTEE is valid only if it is duly compiled.
- In the event of defects covered by the GUARANTEE, the manufacturer will
repair or substitute the product free of charge.
SERVICING AFTER THE GUARANTEE PERIOD:
Any repairs after the period of the GUARANTEE will be charged on the basis
of the parts substituted and the cost of labour.
GUARANTEE CERTIFICATE
TO COMPILE AND SEND IN CASE OF DAMAGE
760 CO
760/10 CO
DEVICE:
Serial number (s.n.)____________________________________________________
DEALER
Stamp:
USER
Surname and name ____________________________________________________
Address __________________________________________ n°_________________
Postcode ______________________ Town/city _____________________________
Telephone____________________________________________________________
Fig.8
ATTENTION!
GUARANTEE.
SE320EC
SE340EC
Date of purchase:
_____/_____/_____
7
PERIODICAL VERIFICATIONS
We warmly suggest doing a check-test of the detector working, car-
ried-out from your installer - at least once a year.
To clean the appliance, use a cloth to remove the dust on the case.
Keep in mind that the sensor has good resistance to commonly used
products such as sprays, detergents, alcohol, glues or paints, but
these products can contain substances that, in large quantities, inter-
fere with the sensor causing false alarms.
It is advisable to ventilate the room when using these products.
Solvent or silicone vapors can deteriorate the gas sensor even during
storage in the warehouse.
The use of the gas detector outside the temperature range and hu-
midity indicated may damage the sensor and reduce its life duration.
It is reminded that the detector is unable to detect leaks that occur
outside the room where it is installed either inside the walls or under
the floor.
TO COMPILED BY THE INSTALLER:
Installation date: ______________________________________________
Substituition date: _____________________________________________
Installation local: ______________________________________________
Instruments' serial number:______________________________________
Sign _______________________________________________________
TECHNICAL CHARACTERISTICS
- Power supply:
230Vca- 50/60Hz 2,3VA / 12Vcc 0,6W.
- Sensor type:
Electrochemical sensor.
- Sensor Life:
Beta 762 CO; SE320EC: 6 years in a domestic environment according to specifications.
Beta 762/10 CO; SE40EC: 10 years in a domestic environment according to specifications.
- Working temperature:
-10°C ... +45°C.
- Relative humidity:
30% ... 90% UR.
- Sensor operation limit:
5000 ppm max 15 minutes
- Maximum storage time:
6 months
- Soglie d'intervento:
l 50 ppm for 70 minutes.
l 100 ppm for 20 minutes.
l 300 ppm for 1 minute.
- Acoustic signal:
80 dB (A) to 1 meter.
- Protection degree:
IP42.
- Electronic self-diagnosis with anomaly signal.
- The CO alarm device conforms to the European standard EN 50291-1: 2010 "Electrical
devices for the detection of carbon monoxide in domestic environments".
Directive 2012/19/UE (Waste Electrical and Electronic Equipment - WEEE):
Information for users:
The crossed out wheeled bin label that can be found on your product indicates that
this product should not be disposed of via the normal household waste stream.
To prevent possible harm to the environment or human health please separate this
product from other waste streams to ensure that it can be recycled in an environmen-
tallysound manner. For more details on available collection facilities please contact
your local government office or the retailer where you purchased this product.
Tecnocontrol Srl
Via Miglioli, n°47 20090 Segrate (MI)
Italy Tel. +39 02 26922890
www.tecnocontrol.it
The manufacturer firm reserves the right to make any aesthetic or functional modification to the without prior
notice at any time.
WARNING
(to read on the frontal plastic involucres)
Stamp
GECA Srl
Via E. Fermi, n°98 25064 Gussago (BS)
Italy Tel. +39 030 3730218
www.gecasrl.it