CPG 351SRCPG12NL Manuale d'uso - Pagina 5
Sfoglia online o scarica il pdf Manuale d'uso per Gamme CPG 351SRCPG12NL. CPG 351SRCPG12NL 9. Countertop step-up ranges
User Manual
351SRCPG12NL | 351SRCPG24NL | 351SRCPG36NL
GAS CONVERSION
NOTE: These units are factory equipped to be used with a Natural Gas connection. However,
they are field convertible to Liquid Propane Gas. A licensed installer is required to complete the
following procedure. Orifices necessary for LP (propane) are provided in a bag tied to the valve
on the front panel. (If you plan to operate the unit at an elevation above 2,000 ft. please see the
below Gas Elevation Guide to find the proper orifice needed for installation.)
1 . Remove the trivets from the top of the appliance.
2 . Remove the burner from the top of the gas pipe.
(Fig. 1)
3 . Replace the orifice fittings into the valve.
NOTE: Unit number on the side of orifice fittings.
(Fig. 2)
4 . Install the front panel knobs.
5 . Before installing the regulator, unscrew the
octagonal cap (Fig. 3 & 4), you can read (NAT) on
the plastic insert out of the cap, flip it over and
snap back in. (Fig. 5)
6 . Continue with installation.
www.cookingperformancegroup.com
Fig. 1
Fig. 2
Fig. 3
Fig. 4
Fig. 5
5