CPG 351FFOP40L Manuale di servizio - Pagina 3
Sfoglia online o scarica il pdf Manuale di servizio per Friggitrice CPG 351FFOP40L. CPG 351FFOP40L 13. Open pot fryers
Anche per CPG 351FFOP40L: Manuale d'uso (16 pagine)
Service Manual
User Manual
351FFOP40N, 351FFOP50N, 351FFOP40L, 351FFOP50L
351CLCPG15NL, 351CLCPG24NL, 351CLCPG36NL,
351CLCPG48NL, 351CLCPG60NL, 351CLCPG72NL
Trouble Shooting
PROBLEM
Pilot light will not stay on
Burner will not turn on
Burner will not turn off
Oil leaking from fryer pot
Oil not reaching temperature
Oil not staying at temperature
Burner flames are small or weak
Burner flame will not light or
maintain flame
Burners are producing a black soot
www.cookingperformancegroup.com
POSSIBLE SOLUTION
• Ensure gas is the correct type for the unit
• Ensure gas supply is turned 'ON'
• Ensure gas supply is at the correct pressure
• Ensure pilot light orifice is clean
• Ensure pilot light stays lit when knob is pressed
• Verify thermopile operation
• Check voltage strength of pilot light
• Check high limit thermostat
• Ensure gas is the correct type for the unit
• Ensure gas supply is turned 'ON'
• Ensure gas supply is at the correct pressure
• Ensure pilot light stays on during startup procedure
• Ensure combination valve knob is turned to 'ON'
• Verify thermopile operation
• Check thermostat is turned 'ON'
• Check thermostat is turned 'OFF'
• Verify thermostat operation
• Check thermostat adjustment
• Check gas combination valve is turned 'OFF'
• Ensure drain valve is closed
• Ensure thermostat capillary wire plug is tight
• Ensure high limit thermostat capillary wire plug is tight
• Check gas combination valve is turned 'ON'
• Check that burners have a good flame when 'ON'
• Check manifold pressure setting matches name plate on unit
• Check thermostat temperature dial setting
• Check thermostat adjustment is correct
• Ensure thermostat probe is clean
• Check gas combination valve is tuned 'ON'
• Check that burners have a good flame when 'ON'
• Check manifold pressure setting matches name plate on unit
• Check thermostat temperature dial setting
• Check thermostat adjustment is correct
• Check gas supply pressure is correct
• Check manifold pressure setting matches name plate on unit
• Check gas combination valve is turned 'ON'
• Check burner openings, wire brush clean if needed
• Check orifice opening for each burner
• Check gas combination solenoid operation
• Check gas combination valve is turned 'ON'
• Check gas supply pressure is correct
• Check manifold pressure setting matches name plate on unit
• Check thermostat temperature dial setting
• Check thermostat adjustment is correct
• Check gas combination solenoid operation
• Ensure correct gas is supplied
• Ensure correct ventilation is set up