CPG 351FFOP40N Manuale di servizio - Pagina 6
Sfoglia online o scarica il pdf Manuale di servizio per Friggitrice CPG 351FFOP40N. CPG 351FFOP40N 13. Open pot fryers
Anche per CPG 351FFOP40N: Manuale d'uso (16 pagine)
Service Manual
351FFOP40N, 351FFOP50N, 351FFOP40L, 351FFOP50L
THERMOSTAT (200-400°F)
•
Audible click can be heard when turned
'ON' / 'OFF'
•
If no click can be heard - Replace Thermostat
•
Disconnect wires from thermostat, check continuity
of thermostat: OFF = No continuity / ON =
Continuity
•
Replace if any checks fail
THERMOSTAT ADJUSTMENT
Thermostat is set at the factory and should maintain
temperatures within 10°F
Recalibrate if needed : if done more than
once, replace
1.
Remove Thermostat dial from shaft (Fig. 31)
NOTE: Be careful not to rotate the dial as that will
change the temperature
2.
Hold the dial shaft, "B" so it does not move
3.
While holding dial shaft, "B", turn calibration
screw, "A"
Clockwise = Decrease Temperature
Counterclockwise = Increase Temperature
4.
Replace dial and allow unit to operate and
temperature to stabilize
5.
Re-adjust if necessary
6.
When done adjusting, seal calibration screw with
glyptol paint or similar product
7.
Reinstall thermostat dial
HIGH LIMIT THERMOSTAT (450°F)
•
Remove wires from high limit thermostat
•
Continuity can be checked across wire connections
•
If no continuity, replace high limit thermostat
•
If high limit cools, continuity may be found, check
oil temperatures
•
High limit thermostat should not 'OPEN' under oil
temperature of 425° F
6
FIG. 9
Thermostat Knob Post
Decrease
Dial
Shaft (B)
Increase
THERMOPILE
•
When heated by pilot light, thermopile should
support 250 millivolts to 750 millivot (500 millivolts
or higher is recommended)
•
Replace if millivolts are less than 250, and/or pilot
flame has been increased in strength
BURNER ORIFICES
•
Burner with poor flames, large yellow tipped flames
or missing sections of flames should be cleaned
•
Good Flame = almost completely blue with a light
blue triangle at the bottom center
•
Clean the burner with a wire brush to remove any
clogs that may have formed
•
If clogs cannot be removed, replace the burner
.
FIG. 10
Calibration
Screw (A)
¼ Turn changes
temperature
18°F
www.cookingperformancegroup.com