CPG 351FFOP50L Manuale di servizio - Pagina 6

Sfoglia online o scarica il pdf Manuale di servizio per Friggitrice CPG 351FFOP50L. CPG 351FFOP50L 13. Open pot fryers
Anche per CPG 351FFOP50L: Manuale d'uso (16 pagine)

Service Manual
351FFOP40N, 351FFOP50N, 351FFOP40L, 351FFOP50L
THERMOSTAT (200-400°F)
Audible click can be heard when turned
'ON' / 'OFF'
If no click can be heard - Replace Thermostat
Disconnect wires from thermostat, check continuity
of thermostat: OFF = No continuity / ON =
Continuity
Replace if any checks fail

THERMOSTAT ADJUSTMENT

Thermostat is set at the factory and should maintain
temperatures within 10°F
Recalibrate if needed : if done more than
once, replace
1.
Remove Thermostat dial from shaft (Fig. 31)
NOTE: Be careful not to rotate the dial as that will
change the temperature
2.
Hold the dial shaft, "B" so it does not move
3.
While holding dial shaft, "B", turn calibration
screw, "A"
Clockwise = Decrease Temperature
Counterclockwise = Increase Temperature
4.
Replace dial and allow unit to operate and
temperature to stabilize
5.
Re-adjust if necessary
6.
When done adjusting, seal calibration screw with
glyptol paint or similar product
7.
Reinstall thermostat dial
HIGH LIMIT THERMOSTAT (450°F)
Remove wires from high limit thermostat
Continuity can be checked across wire connections
If no continuity, replace high limit thermostat
If high limit cools, continuity may be found, check
oil temperatures
High limit thermostat should not 'OPEN' under oil
temperature of 425° F
6
FIG. 9

Thermostat Knob Post

Decrease
Dial
Shaft (B)
Increase

THERMOPILE

When heated by pilot light, thermopile should
support 250 millivolts to 750 millivot (500 millivolts
or higher is recommended)
Replace if millivolts are less than 250, and/or pilot
flame has been increased in strength

BURNER ORIFICES

Burner with poor flames, large yellow tipped flames
or missing sections of flames should be cleaned
Good Flame = almost completely blue with a light
blue triangle at the bottom center
Clean the burner with a wire brush to remove any
clogs that may have formed
If clogs cannot be removed, replace the burner
.
FIG. 10
Calibration
Screw (A)
¼ Turn changes
temperature
18°F
www.cookingperformancegroup.com