CPG 351GTUCPG24N Manuale d'uso - Pagina 3
Sfoglia online o scarica il pdf Manuale d'uso per Piano di cottura CPG 351GTUCPG24N. CPG 351GTUCPG24N 11. Gas countertop chrome plated griddles with thermostatic controls
SAFETY PRECAUTIONS
CAUTION:
Potential hazard or unsafe practice could result in minor or moderate injury and product or
property damage.
NOTICE:
• Local codes regarding installation vary greatly from one area to another. The National Fire
Protection Association, Inc., states in its NFPA96 latest edition that local codes are "Authority
Having Jurisdiction" when it comes to requirement for installation of equipment. Therefore,
installation should comply with all local codes.
This product is intended for commercial use only. Not for residential use.
•
WARNING:
• Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any
other appliance.
• Improper installation, adjustment, alteration, service, or maintenance could lead to property
damage, injury, or death. Read the installation, operating, and maintenance instructions
thoroughly before installing or servicing CPG equipment. This manual must be retained
for future reference.
• Instructions must be posted in a prominent location. All safety precautions must be taken in the
event the user smells gas. Safety information can be obtained from your local gas supplier.
• A factory authorized agent should handle all maintenance and repair. Prior to conducting any
maintenance or repair work contact an authorized service agency.
GAS PRESSURE:
The appliance and its individual shutoff valve (to be supplied by user) must be disconnected from the
gas supply piping system during any pressure testing of that system at test pressures in excess of
1/2 PSI (3.45 kPa). The appliance must be isolated from the gas supply piping system by closing its
individual manual shut-off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than 1/2 PSI (3.45 kPa).
SERIAL PLATE
NOTE:
The serial plate is located
on the right side of the unit.
www.CookingPerformanceGroup.com
USER MANUAL
Made in China
Item # 351GTUCPG24N
Model # G24T
GRILL COUNTER 24" THERM
Total BTU: 60,000
Gas Type: Natural gas
Manifold Pressure: 6 in.w.c
Orifice Size: # 41
CLEARANCE REQUIREMENTS:
Combustible Sides: 6"
Combustible Back: 6"
Serial # 1101000001
Conforms to ANSI STD Z83.11-2016 and certified to CSA 1.8 STD- 2016
Conforms to NSF / ANSI STD. 4
3