CPI 1.2M Ku-BAND Series Manuale di montaggio - Pagina 7
Sfoglia online o scarica il pdf Manuale di montaggio per Antenna CPI 1.2M Ku-BAND Series. CPI 1.2M Ku-BAND Series 15.
CPI Satcom & Antenna Technologies
SUGGESTED IN-GROUND FOUNDATION
12.0"
SECTION A - A
NOTES:
1.
2 1/2" schedule 40 pipe should conform to ASTM A53.
2.
All concrete should conform to building code standards and have a minimum compressive
strength of 3000 PSI at 28 days. (Per ACI-318-77)
3.
Soil bearing capacity should be no less than 2000 PSF.
4.
Concrete should be poured against undisturbed soil.
5.
Allow concrete 24 hours set time before installation of antenna.
6.
The antenna should be properly grounded to meet applicable local codes.
7.
Minimum depth as shown or extend to local frost line.
8.
Foundation meets the design requirements as set forth by the uniform building code.
(1982 edition)
(ABOVE DESIGN IS A SUGGESTED FOUNDATION ONLY. CPI DOES NOT REPRESENT OR
WARRANT THAT ANY PARTICULAR DESIGN OR SIZE OF FOUNDATION IS APPROPRIATE FOR
ANY LOCALITY OR EARTH STATION INSTALLATION.)
30.0"
A
30.0"
SEE NOTE #7
FIGURE 1.
6
1.2M Ku-BAND SERIES 1122
2 1/2" SCH 40 PIPE
(2.88" O.D.)
A
45
4096-1000