GENERAL INFORMATION
Sensor:
Gases:
Calibration:
R-134a
HFO-1234yf
The LDA1000H gives an indication within 5 seconds when the probe is
held stationary at 5mm (0.2") from a calibrated leak source of R-134a
set for 3 g / yr. per EN14624:2012.
Audible Alarms:
Visual Alarms:
Operating
Temperature:
Power:
Battery Life:
Dimensions:
Probe:
Weight:
Certifications:
LDA1000H Specifications
State of the art E_MOS
Sensitive to CFC, HCFC, HFC and HFO refrigerants.
Sensitive to the Hydrogen trace gas in 95%
N2, 5% H2 mixture. Sensitive to NH3 and HC
refrigerants. CAUTION: This leak detector is
not intrinsically safe. Use in well ventilated
areas. Instrument factory calibrated to meet the
requirements of SAE J2791 and J2913.
While moving 3" / sec. (75mm / sec.) at 3/8"
(9.5mm) from calibrated leak source.
L = 14 g / yr. (0.5 oz / yr.) or greater
M = 7 g / yr. (0.25 oz / yr.) or greater
S = 4 g / yr. (0.15 oz / yr.) or greater
SC = 4g / yr. (0.15 oz / yr.) or greater in 500
ppm. or less by weight R-134a contaminated
atmosphere.
L = 14 g / yr. (0.5 oz / yr.) or greater
M = 7 g / yr. (0.25 oz / yr.) or greater
S = 7 g / yr. (0.25 oz / yr.) or greater
SC = 4g / yr. (0.15 oz / yr.) or greater in
500 ppm. or less by weight HFO-1234yf
contaminated atmosphere.
High pitched wide tone range audible alarm
alarm in settings L, M and S. Low pitched
audible alarm in SC settings.
An 8 segment bar-graph LED display shows
the relative leak size.
-18 to 60˚C (0 to 140˚F)
Three size "C" alkaline batteries (NEDA/ANSI
14A)
50 hours minimum at 77˚F (25˚C). Battery life
depends on cell chemistry and ambient con-
ditions. Alkaline batteries provide longest life.
Cold ambient conditions decrease battery life.
The LDA1000H turns itself off after 10 minutes
of inactivity—START button not pressed—to
further prolong battery life.
Instrument (L x W x H): 10" x 2.3" x 2" 254mm
x 59mm x 51mm
15" (380mm) long, .25" (6.4mm) diameter
1 lb 2 oz (500 g)
Complies with European Standard
EN14624:2012.
technology
®
SAE J2791 and J2913