DGF Fabrications L1 Manuale di istruzioni per l'installazione e la manutenzione - Pagina 13

Sfoglia online o scarica il pdf Manuale di istruzioni per l'installazione e la manutenzione per Camino da interno DGF Fabrications L1. DGF Fabrications L1 14. Gas effect fires (natural gas & lpg) for decorative purposes only

Pilot goes out when knob is released, or goes out at regular intervals
Check that the thermocouple is not loose.
Thermocouple is damaged and needs replacing.
Thermocouple operated magnetic valve faulty – replace gas valve
Blue flame
It normally takes 20 minutes for the fire to reach correct working temperature, by which time most of
the blue flames should have gone. Continuous blue flame is caused by poor coal layout or excessive up
draught of the flue. Seek advice from your manufacturer.
Poor gas pressure will also cause blue flame. Check gas pressure.
Poor Flame picture
Check gas pressure
Ensure that there is no obvious obstruction to gas supply pipe
Re-lay the simulated coals, pebbles, logs or driftwood as shown on the relevant illustrations within this
booklet. Only do this when fire is cold or alternatively use a non combustible tool.
These fires are made in Darlington and there destinations are distributed throughout England, Ireland, Scotland,
Wales, Isle of Wight, and Spain. (GB – IE – ES).
Units 1-3 Vulcan St, Edward St Industrial Estate, Darlington. DL1 2UL – Tel: 01325 281304; Fax: 01325 481889
COUNTRY OF DESTINATION
13
DGF Fabrications;