Avtech AVT1206A Manuale d'uso - Pagina 4
Sfoglia online o scarica il pdf Manuale d'uso per Telecamera di sicurezza Avtech AVT1206A. Avtech AVT1206A 8. Ir dome camera
CONNECTION
1. DC12V Input Terminal
Connect the power terminal of the camera to a DC 12V regulated power supply.
Note: Please use the correct power adaptor, DC12V (regulated), to operate this unit. The power tolerance of
this unit is DC12V ± 10%. Over maximum DC 12V power input will damage this unit.
2. Video Output Connector (VIDEO OUT)
Connect the camera video output to the video input of a DVR with 75Ω coaxial cable.
Note: To ensure the camera has sufficient protection against moisture, an extra waterproof measure, such as
by using an insulating tape, must be used to cover the power and video connectors after connection.
IR LED BRIGHTNESS CONTROL (PWM)
This function is used to control the brightness of IR LEDs. The brightness is set to the maximum by default.
Note: This function shows only on our brand's HD CCTV DVR with specific firmware version. If you
don't see this option, try upgrading your DVR or check with your installer.
For example, if you feel the image is too bright when the night mode is on, resulting a little bit overexposure,
you can use this function to modify as you wish.
On the DVR live view, right click to show the DVR main menu, and select ADVANCED CONFIG
DCCS DCCS MENU.
CAMERA
DETECTION
ALERT
NETWORK
DISPLAY
RECORD
DCCS
NOTIFY
EXIT
In DCCS SETUP, click the value to change it from 0 ~ 100.
DCCS SETUP
IR1 BRIGHTNESS USER
ADVANCED CONFIG
CH1
CH2
CH3
OSD MENU
DCCS MENU
F.W.
DEVICE
CONNECTION
100
CH4
SETUP
SETUP
E8
AVT SERIES
OK