Anche per Dell 8: Manuale di aggiornamento (44 pagine), Manuale di aggiornamento (21 pagine), Manuale di aggiornamento (14 pagine), Manuale di installazione (7 pagine), Manuale d'uso (28 pagine), Manuale d'uso (32 pagine), Manuale d'uso (44 pagine), Manuale di avvio rapido (2 pagine), Manuale di avvio rapido (2 pagine)

Dell 8 Manuale d'uso
Corrective
If you have configured hot spares, the PERC card automatically tries to use one of them to
Action:
rebuild a physical disk that is in a failed state. The automatic rebuild will not be available if
there is no hot spare with enough capacity to rebuild the failed physical disk. You must make
sure a physical disk with enough storage in the subsystem is set as a hot spare for rebuilding
the physical disk.

Virtual Disk Fails During Rebuild Using A Global Hot Spare

Issue:
A virtual disk fails during rebuild while using a global hot spare.
Description:
The global hot spare goes back to Hotspare state and the virtual disk goes to Failed state.

Virtual Disk Fails During Rebuild Using A Dedicated Hot Spare

Issue:
A virtual disk fails during rebuild while using a dedicated hot spare.
Description:
The dedicated hot spare goes to Ready state and the virtual disk goes to Failed state.

Virtual Disk Fails Rebuild Using A Dedicated Hot Spare

Issue:
A virtual disk fails during rebuild while using a dedicated hot spare.
Description:
The dedicated hot spare goes to Ready state and the virtual disk goes to Failed state.

Physical Disk Takes A Long Time To Rebuild

Issue:
A physical disk is taking longer than expected to rebuild.
Description:
A physical disk takes longer to rebuild when under high stress. For example, there is one
rebuild I/O operation for every five host I/O operations. You cannot add a second virtual disk to
a disk group while the virtual disk in that disk group is undergoing a rebuild. The firmware does
not allow you to create a virtual disk using the free space available in a disk group if a physical
disk in a virtual disk group is undergoing a rebuild operation.

SMART Errors

Self Monitoring and Reporting Technology (SMART) monitors the internal performance of all motors, heads, and
physical disk electronics and detects predictable physical disk failures.
NOTE: For information about where to find reports of SMART errors that can indicate hardware failure, see the
Chassis Management Controller for Dell PowerEdge VRTX User's Guide at dell.com/esmmanuals.

SMART Error Detected On A Physical Disk In A Redundant Virtual Disk

Issue:
A SMART error is detected on a physical disk in a redundant virtual disk.
Corrective
Perform the following steps:
Action:
30